Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/12870
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorAcaro R., José A.-
dc.contributor.authorQuispe E., Jeannie L.-
dc.creatorQuispe E., Jeannie L.-
dc.creatorAcaro R., José A.-
dc.date.accessioned2018-08-01T01:37:46Z-
dc.date.available2018-08-01T01:37:46Z-
dc.date.issued2017-06-01-
dc.identifier.citationAcaro R, J., & Quispe E., J. (2017). Comportamiento de torre de lavado a nivel de escala para la remoción de H2S de un reactor anaeróbico de flujo ascendente. Revista TECNIA, 27(1), 85. https://doi.org/10.21754/tecnia.v27i1.130es
dc.identifier.issn2309-0413-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/12870-
dc.description.abstractNuestro equipo en esta oportunidad hizo una simulación de una torre de lavado, la cual la aplicamos en el reactor UASB, a manera de escala construimos una torre de lavado compuesta por difusores, una cama de sólidos hecha de material de esponja, un tubo de acrílico y todas las conexiones que conducen el biogás con H2S. Los componentes a eliminar y/o remover fueron los gases que salen del reactor, en especial del H2S (gas odorífero y toxico que a grandes concentraciones pude llevar a la muerte y como resultado de sus reacciones con el ambiente puede causar daños en las estructuras con la cual este en contacto) mediante la oxidación con el oxígeno disuelto que proveen las microalgas presentes en el agua de la laguna terciara utilizada. Esta torre de lavado la montamos en las instalaciones de CITRAR‐UNI con el permiso del operador y vimos el comportamiento que tiene esta torre, mediante los monitoreos de oxígeno disuelto, temperatura, pH y sulfatos que realizamos durante tres semanas de monitoreo. Como resultados obtuvimos que la torre de lavado sí oxidaba y removía la contracción de H2S, ya que cuando pasaba el tiempo se consumía el oxígeno disuelto, además de esto también en el monitoreo de sulfatos pudimos observar un aumento de este parámetro es decir la torre si estaba consumiendo en H2S, y por esta razón también disminuyo el olor fétido que produce este gas.es
dc.description.abstractThe present work reports the simulation of a wet scrubber coupled to an UASB reactor. The scrubber consisted of baffles, packed bed of sponge material, an acrylic tube and all the connections necessary to bring the H2S‐ladden biogas. The purpose of the equipment is to eliminate some of the gases coming out of the reactor, through their oxidation by the dissolved oxygen provided by the microalgae present in the water from the tertiary lagoon. Hydrogen sulfide is a foulsmelling and toxic gas which can cause death at high concentrations, and can also cause damage to the structures with which it comes into contact. The scrubber was installed on the site of CITRAR‐UNI and the behavior of the equipment was monitored during three weeks by following the temperature, pH and the concentrations of sulfates and dissolved oxygen. The results have shown that the scrubber was effectively an oxidizing environment which was removing H2S, since the dissolved oxygen was actually consumed gradually. It was also observed that the sulfate concentration was increasing, indicating a consumption of H2S, which was also confirmed by a reduction in the odor of the gas.en
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.relationinfo:eu-repo/semantics/articlees
dc.relation.ispartofseriesVolumen;27-
dc.relation.ispartofseriesNúmero;1-
dc.relation.urihttp://revistas.uni.edu.pe/index.php/tecnia/article/view/130es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectTorre de lavadoes
dc.subjectReactor UASBes
dc.subjectRemoción de sulfuro de hidrógenoes
dc.titleComportamiento de torre de lavado a nivel de escala para la remoción de H2S de un reactor anaeróbico de flujo ascendentees
dc.titleBehavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactoren
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.journalTECNIAes
dc.description.peer-reviewRevisión por pareses
dc.identifier.doihttps://doi.org/10.21754/tecnia.v27i1.130es
dc.contributor.emailjaar0512@gmail.comes
dc.contributor.emaillaleshka.qe@gmail.comes
dc.contributor.emailsalasdepazm@gmail.comes
Aparece en las colecciones: Vol. 27 Núm. 1 (2017)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TECNIA_Vol.27-n1-Art. 2.pdf751,06 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI