Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/13780
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Pereyra, Antonio | - |
dc.contributor.author | Zevallos, María I. | - |
dc.contributor.author | Ricra, José | - |
dc.contributor.author | Tello, Julio C. | - |
dc.creator | Tello, Julio C. | - |
dc.creator | Ricra, José | - |
dc.creator | Zevallos, María I. | - |
dc.creator | Pereyra, Antonio | - |
dc.date.accessioned | 2018-09-18T13:51:41Z | - |
dc.date.available | 2018-09-18T13:51:41Z | - |
dc.date.issued | 2016-12-01 | - |
dc.identifier.citation | Pereyra, A., Zevallos, M., Ricra, J., & Tello, J. (2016). Caracterizando un detector CCD para uso astronómico: proyecto OAUNI. TECNIA, 26(2), 20. https://doi.org/10.21754/tecnia.v26i2.54 | es |
dc.identifier.issn | 2309-0413 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/13780 | - |
dc.description.abstract | El presente trabajo verificó las capacidades del detector CCD que forma parte del instrumental asociado al proyecto del Observatorio Astronómico de la UNI. Fueron medidos la respuesta lineal del detector CCD de la cámara SBIG STXL6303E, así como su ganancia y el ruido de lectura asociados. La respuesta lineal a la luz incidente del detector es extremadamente lineal (R2=99.99%), su ganancia efectiva es 1.65 ± 0.1 e-/ADU y su ruido de lectura 12.2 e-. Estos valores están de acuerdo con los proporcionados por el fabricante. Se confirma que el detector analizado es extremadamente preciso para realizar medidas con fines astronómicos. | es |
dc.description.abstract | This work verifies the instrumental characteristics of the CCD detector which is part of the UNI astronomical observatory. We measured the linearity of the CCD detector of the SBIG STXL6303E camera, along with the associated gain and readout noise. The linear response to the incident light of the detector is extremely linear (R2 =99.99%), its effective gain is 1.65 ± 0.01 e- /ADU and its readout noise is 12.2 e-. These valúes are in agreement with the manufacturen We confirm that this detector is extremely precise to make measurements for astronomical purposes. | en |
dc.format | application/pdf | es |
dc.language.iso | eng | en |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.relation.ispartofseries | Volumen;26 | - |
dc.relation.ispartofseries | Número;2 | - |
dc.relation.uri | http://revistas.uni.edu.pe/index.php/tecnia/article/view/54 | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Dispositivos de carga acoplada | es |
dc.subject | Linealidad | es |
dc.subject | Ruido de lectura | es |
dc.title | Caracterizando un detector CCD para uso astronómico: proyecto OAUNI | es |
dc.title | Characterizing a CCD detector for astronomical purposes: OAUNI project | en |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.journal | TECNIA | es |
dc.description.peer-review | Revisión por pares | es |
dc.identifier.doi | https://doi.org/10.21754/tecnia.v26i2.54 | es |
dc.contributor.email | apereyra@igp.gob.pe | es |
Aparece en las colecciones: | Vol. 26 Núm. 2 (2016) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TECNIA_Vol.26-n2-Art. 8.pdf | 3,14 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: