dc.description.abstractLa atención a emergencias operativas en los primeros 220 kilómetros del Sistema de Transportes de Hidrocarburos por Ductos (STD) del Proyecto Camisea, resulta un desafío desde el punto de vista técnico y logístico. Principalmente, causado por las condiciones geográficas que se presentan en las zonas de trabajo. Se evaluará la aplicabilidad técnica económica de tuberías flexibles como alternativa para la atención de emergencias operativas en ductos de transporte de Líquidos de Gas Natural (LGN). En la investigación se realizaron modelamientos hidráulicos, esto con el objetivo de caracterizar y simular las condiciones operativas de un poliducto. Además, se identificaron las Zonas de Alto Riesgo (ZAR), que son las zonas con alta probabilidad de ocurrencia de ruptura del ducto LGN. En resumen, estas áreas pertenecen a la Zona Sierra del STD LGN y se identificaron con el modelamiento semicuantitativo usando el software Pipeline Integrity Managment System (PIMS). Asimismo, se seleccionó una de las áreas con el propósito de realizar el análisis integral para identificar los recursos requeridos para la atención a una emergencia operativa. En este escenario hipotético se planteó el uso de un by pass. Se instaló tuberías flexibles enrollables reemplazando al by pass tradicional fabricado con tuberías rígidas de acero al carbono. Se implementó un sistema de selección óptima de un by pass en base a análisis técnicos económicos, con el fin de reducir costos operativos para atender una emergencia operativa en el ducto de LGN del proyecto Camisea, optimizando tiempos, logística, recursos humanos, con la intención de restablecer el STD LGN en el menor tiempo posible. Finalmente, durante la atención a una emergencia operativa en una ZAR, el sistema de tuberías flexibles fue más eficaz y eficiente mostrando ahorros significativos para la operadora en comparación al uso de tuberías rígidas.es
dc.description.abstractAttention to operational emergencies in the first 220 kilometers of the Pipeline Hydrocarbon Transportation System (STD) of the Camisea Project is a challenge from a technical and logistical point of view. Mainly, caused by the geographical conditions that occur in the work areas. The economic technical applicability of flexible pipes will be evaluated as an alternative for the attention of operational emergencies in pipelines for the transportation of Natural Gas Liquids (NGL). In the research, hydraulic modeling was carried out in order to characterize and simulate the operating conditions of a pipeline. In addition, the High Risk Zones (ZAR) were identified, which are the areas with a high probability of rupture of the LGN pipeline. In summary, these areas belong to the Sierra Zone of the STD LGN and were identified with semi-quantitative modeling using the Pipeline Integrity Management System (PIMS) software. Likewise, one of the areas was selected to conduct a comprehensive analysis to identify the resources required to attend to an operational emergency. In this hypothetical scenario, the use of a bypass was considered. Rollable flexible pipes were installed replacing the traditional by-pass made with rigid carbon steel pipes. An optimal selection system for a bypass was implemented based on technical economic analysis, to reduce operating costs to attend an operational emergency in the NGL pipeline of the Camisea project, optimizing times, logistics, human resources, to reset the STD LGN in the shortest time possible. Finally, during the attention to an operational emergency in a ZAR, the flexible pipe system was more effective and efficient, showing significant savings for the operator compared to the use of rigid pipes.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectTuberíases
dc.subjectProyectos hidráulicoses
dc.subjectProyecto Gas de Camiseaes
dc.titleEvaluación integral del uso de tuberías flexibles en condiciones de emergencias operativas en ductos del LGN, en la zona sierra del proyecto Camiseaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero de Petróleo y Gas Naturales
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería de Petróleo, Gas Natural y Petroquímicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería de Petróleo y Gas Naturales
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-4191-3901es
renati.author.dni70103069-
renati.advisor.dni08064104-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline724056-
renati.jurorArgumé Chávez, Edgard Américo-
renati.jurorNavarro Cornejo, William Romeo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.07.03es
Appears in Collections:Ingeniería de Petróleo

Files in This Item:
File Description SizeFormat 
sinchitullo_gv.pdf5,74 MBAdobe PDFView/Open