dc.description.abstract | El presente informe tiene como objetivo identificar, medir, analizar y proponer diversas alternativas y acciones que nos permitan reducir y controlar el consumo de energía eléctrica que tiene la terminal Norte Multipropósito del Callao, en línea con estándares de eficiencia energética y buscando oportunidades de ahorros en la facturación eléctrica. APM Terminals Callao es la empresa concesionaria de la terminal Norte Multipropósito del Callao y brinda servicios portuarios para sus clientes. Se ha observado que los consumos de energía eléctrica y su facturación asociada no guardan una relación directa con los niveles de volúmenes y/o carga que mueve el terminal mes a mes. Lo que se ha implementado es un sistema de medición, que permite registrar los consumos de potencia y energía de forma global y segregada de sus diversas líneas de servicios. Se ha realizado un análisis de los datos históricos encontrados y se han desarrollado acciones con impacto directo en la reducción de la facturación eléctrica: Como la revisión de precios y nuevo contrato del suministro eléctrico, el uso de la tecnología LED como reemplazo de los antiguos sistemas de iluminación a base de vapor de sodio y el uso de sistemas de almacenamiento de energía para controlar la potencia durante el horario de hora punta. Se ha instalado un pequeño sistema solar para una carga, no critica, de iluminación en un muelle y que requiere bajo consumo de energía. Finalmente, se evalúa los consumos y gastos por energía reactiva. | es |
dc.description.abstract | The purpose of this report is to identify, measure, analyze and propose some alternatives and actions that can reduce and control the consumption of electricity at the North Multipurpose Terminal in Callao, in line with energy efficiency standards and looking for savings in the electricity billing. APM Terminals Callao is the concessionaire of the North Multipurpose Terminal in Callao and provides port services for its clients. Monthly, it has been noted that there are not mach between electricity consumption and the volumen that the terminal moves. According to said, it has been implemented a measurement system, that can record the power and energy as a segregated way for its types of services. An analysis of the historical data has been carried out and actions have been developed, in order to have a direct impact on the reduction of the electricity billing: Such as the revision of the power purchase agreement, replace the old High Presure Sodium technology by LED for external lighting poles and use a battery energy storage system to mitigate the power during peak hours. Small solar panel system has been installed for non-critical loads that require low energy consumption. Finally, consumption and expenses for reactive energy were evaluated. | en |
dc.description.uri | Trabajo de suficiencia profesional | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | APM Terminals Callao | es |
dc.subject | Consumo energético | es |
dc.subject | Terminal Norte Multipropósito del Callao | es |
dc.title | Diagnóstico situacional y mejoramiento del consumo energético en la terminal multipropósito muelle Norte del Callao | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Electricista | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Eléctrica y Electrónica | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Eléctrica | es |
thesis.degree.program | Ingeniería | es |
renati.advisor.orcid | https://orcid.org/0000-0002-3004-1984 | es |
renati.author.dni | 40448193 | - |
renati.advisor.dni | 09259403 | - |
renati.type | http://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 711046 | - |
renati.juror | Huayllasco Montalva, Carlos Alberto | - |
renati.juror | Palma García, Modesto Tomás | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.02.01 | es |
Aparece en las colecciones: | Ingeniería Electrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
torres_ma.pdf | 5,46 MB | Adobe PDF | Visualizar/Abrir | |
informe_de_similitud.pdf | 107,47 kB | Adobe PDF | Visualizar/Abrir | |
torres_ma(acta).pdf | 116,86 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: