Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/28097
Título : | Diseño de ascensor basado en normas nacionales e internacionales para mejorar la seguridad de personas en edificio de Comas |
Autor : | Huamán Ramos, Fernando Santos |
Asesor : | Padilla Ríos, Aurelio Marcelo |
Palabras clave : | Ascensores;Normas internacionales;Comas, Lima (Perú : Distrito) |
Fecha de publicación : | 2024 |
Editorial : | Universidad Nacional de Ingeniería |
Resumen : | El presente estudio tiene el propósito de diseñar un ascensor con las normas que involucran la seguridad en su proceso de fabricación cumpliendo las normas nacionales e internacionales.
Estas normas en los cuales nos apoyamos para el diseño del ascensor son para salvaguardar la integridad de las personas a transportar, diseñando un ascensor seguro.
Durante el proceso del diseño del ascensor se ha realizado cálculos de las cargas a los cuales se ha aplicado los valores de seguridad recomendados por las Normas y de otros autores.
La metodología es aplicada, cuantitativa, descriptivo y no experimental, respaldando sus cálculos de diseño con los resultados obtenidos de los cálculos con resultados con buen valor de confianza por los márgenes de seguridad recomendados y asumidos.
Se concluye que se realizó el cálculo de un ascensor considerando la premisa del cumplimiento de las normas vigente tanto local, así como internacional para conseguir una seguridad en su funcionamiento que queda también plasmada en la reducción de las paralizaciones y asegurar la vida útil de sus componentes. The purpose of this study is to design an elevator with the standards that involve safety in its manufacturing process, complying with national and international standards. These standards on which we rely for the design of the elevator are to safeguard the integrity of the people to be transported, designing a safe elevator. During the elevator design process, load calculations have been made to which the safety values recommended by the Standards and other authors have been applied. The methodology is applied, quantitative, descriptive and non-experimental, supporting its design calculations with the results obtained from the calculations with results with good confidence value for the recommended and assumed safety margins. It is concluded that the calculation of an elevator was carried out considering the premise of compliance with current local and international standards to achieve safety in its operation that is also reflected in the reduction of stoppages and ensuring the useful life of its components. |
URI : | http://hdl.handle.net/20.500.14076/28097 |
Derechos: | info:eu-repo/semantics/openAccess |
Aparece en las colecciones: | Ingeniería Mecánica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
huaman_rf.pdf | 7,33 MB | Adobe PDF | Visualizar/Abrir | |
huaman_rf(acta).pdf | 799,58 kB | Adobe PDF | Visualizar/Abrir | |
informe_de_similitud.pdf | 1,22 MB | Adobe PDF | Visualizar/Abrir | |
carta_de_autorización.pdf | 1,39 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por:
