Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/28621
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMesa, Ruddy-
dc.contributor.authorKhan, Sabir-
dc.contributor.authorSotomayor, Maria D. P. T.-
dc.contributor.authorPicasso, Gino-
dc.creatorPicasso, Gino-
dc.creatorSotomayor, Maria D. P. T.-
dc.creatorKhan, Sabir-
dc.creatorMesa, Ruddy-
dc.date.accessioned2025-10-29T01:39:34Z-
dc.date.available2025-10-29T01:39:34Z-
dc.date.issued2022-05-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/28621-
dc.description.abstractMethylmercury (MeHg) is one of the most toxic organic mercury compounds found in the environment. The continuous exposure of human beings to this highly toxic compound may damage their nervous system. The present work reports the development and application of a novel electrochemical sensing technique for the quantification of MeHg using a modified carbon paste electrode with multi-walled carbon nanotubes (MWCNTs) combined with ion imprinted polymer, which is highly selective toward MeHg (CPE/MWCNTs/IIP-MeHg) detection. The ion imprinted polymer was synthesized using 2-mercaptobenzothiazole (MBT), acrylic acid (AA) and MeHg employed as ligand, functional monomer and template ion, respectively, and the synthesized material was characterized by Raman spectroscopy and SEM-EDX. Both the proposed and control sensors were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical measurements were carried out using differential pulse stripping voltammetry (DPSV), and a well-defined anodic peak observed at about +0.138 V (vs. Ag/AgCl) was recorded for MeHg. The application of the CPE/MWCNTs/IIP-MeHg sensor (which increased the charge transfer on the electrode surface) under the DPSV-based electrochemical method (which enhanced the signal intensity) made the detection technique highly sensitive and selective for the quantification of methylmercury. Under optimum experimental conditions, the proposed sensor exhibited a linear response range of 560–610 µg L−1 and a detection limit of 0.538 µg L−1, with acceptable relative error values ≤1% when applied for the detection of MeHg in real water samples.en
dc.description.sponsorshipEste trabajo fue financiado por el Fondo Nacional de Desarrollo Científico, Tecnológico y de Innovación Tecnológica (Fondecyt - Perú) en el marco del “Desarrollo de dispositivos analíticos para la cuantificación de contaminantes emergentes en fuentes acuíferas de zonas industriales del Perú, usando polímeros molecularmente impresos biomiméticos adaptados a sistemas Flujo Lateral (FL), lámina de cromatografía en capa delgada (CCD) y sensores ópticos” [número de contrato 023-2019]es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherMDPI Open Access Journalses
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectMethylmercury quantificationes
dc.subjectElectrochemical sensores
dc.titleUsing Carbon Paste Electrode Modified with Ion Imprinted Polymer and MWCNT for Electrochemical Quantification of Methylmercury in Natural Water Sampleses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doihttps://doi.org/10.3390/bios12060376es
dc.relation.isPartOfurn:issn:2079-6374es
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85es
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.04.05es
Aparece en las colecciones: Ingeniería Mecánica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
mesa_r.pdf1,72 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI