dc.description.abstractEl presente trabajo de investigación abarca el problema de: la evaluación de reportes de análisis de aceite para optimizar los criterios de lubricación de equipos trackless, con el objetivo de: proponer un modelo de evaluación de datos de aceite basado en Estandar ASTM para mejorar los criterios de lubricación de equipos trackless en una mina subterránea, la unidad de análisis son los resultados de muestras de aceite usado de los equipos trackless de una mina subterránea, los datos se han recolectado base de datos Smart Lab durante el periodo diciembre de 2001 a noviembre 2002, la investigación es del tipo aplicada, enfoque cuantitativo, el nivel correlacional - explicativo, el diseño es cuasi experimental y transversal. Mediante esta investigación, el desgaste de piezas móviles lubricadas se reduce, las estrategias para una mejor evaluación de reportes de análisis de aceite, detecta aquellos reportes que superan los límites condenatorios, dando mayor énfasis de interpretación al personal analista de mantenimiento de lubricación. Los resultados de la investigación han permitido contrastar las hipótesis planteadas, logrando los limites condenatorios en parámetros de contaminación y desgaste de los modelos MT 2010, ST 1030, R1300G, R1600H, 853 s8, Boltec S, Boomer S1D, DD311, Simba s7. Las principales conclusiones son: los límites condenatorios obtenidos por estadística, siguiendo las pautas del estándar ASTM 7720-D, son posibles de hallar con data de reportes de aceite usado de al menos 1 año cumpliendo con los cambios de aceite en la frecuencia estandarizada por el manual del equipo y validada por el área de mantenimiento; de igual forma se corroboran los aceites que correspondan al indicado mediante línea base y se eliminan valores atípicos; Se ha logrado el buen funcionamiento de los equipos que se encuentren dentro de los límites condenatorios La correcta interpretación de los resultados de análisis de aceite usado, debe tener una base histórica del componente analizado basándose en tendencias.es
dc.description.abstractThis research covers the problem of: evaluating oil analysis reports to optimize lubrication criteria for trackless equipment, with the objective of: proposing an oil data evaluation model based on ASTM Standard to improve lubrication criteria for trackless equipment in an underground mine, the analysis unit is the results of used oil samples from trackless equipment in an underground mine, the data have been collected from the Smart Lab database during the period from December 2001 to November 2002, the research is of the applied type, quantitative approach, correlational - explanatory level, the design is quasi-experimental and transversal. Through this research, the wear of lubricated moving parts is reduced, the strategies for a better evaluation of oil analysis reports, detects those reports that exceed the condemnatory limits, giving greater emphasis to the interpretation of the lubrication maintenance analyst staff. The results of the investigation have allowed to contrast the hypotheses raised, achieving the condemnatory limits in contamination and wear parameters of the models MT 2010, ST 1030, R1300G, R1600H, 853 s8, Boltec S, Boomer S1D, DD311, Simba s7. The main conclusions are: the condemnatory limits obtained by statistics, following the guidelines of the ASTM 7720-D standard, are possible to find with data from used oil reports of at least 1 year complying with the oil changes at the frequency standardized by the equipment manual and validated by the maintenance area; in the same way they corroborate the oils that correspond to the one indicated by the baseline and atypical values are eliminated; The proper functioning of the equipment that is within the condemnatory limits has been achieved. The correct interpretation of the results of the used oil analysis must have a historical basis of the analyzed component based on trends.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectEquipos Trackless -es
dc.subjectMina subterráneaes
dc.subjectTribologíaes
dc.subjectLubricaión de equiposes
dc.subjectEstándar ASTM 7720-Des
dc.titleEvaluación de reportes de aceite según estándar ASTM para optimizar los criterios de lubricación de equipos trackless en mina subterráneaes
dc.typeinfo:eu-repo/semantics/masterThesises
thesis.degree.nameMaestro en Ingeniería con Mención en Gerencia e Ingeniería de Mantenimientoes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Mecánica. Unidad de Posgradoes
thesis.degree.levelMaestríaes
thesis.degree.disciplineMaestría en Ingeniería con Mención en Gerencia e Ingeniería de Mantenimientoes
thesis.degree.programMaestríaes
renati.advisor.orcidhttps://orcid.org/0009-0007-6270-6171es
renati.author.dni72781985-
renati.advisor.dni07188676-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#maestroes
renati.discipline713077-
renati.jurorSilva Vásquez, Wilson José-
renati.jurorRodríguez Bustinza, Ricardo Raúl-
renati.jurorPantoja Carhuavilca, Hermes Yesser-
renati.jurorZanabria Alán, Luis Enrique-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.03.02es
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
rojas_vn.pdf4,49 MBAdobe PDFVisualizar/Abrir
rojas_vn(acta).pdf302,28 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf733,01 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf317,28 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI