Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/28323
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMendoza Apolaya, Atilio-
dc.contributor.authorDe la Cruz García, Carina Jhanina-
dc.creatorDe la Cruz García, Carina Jhanina-
dc.date.accessioned2025-07-11T19:20:36Z-
dc.date.available2025-07-11T19:20:36Z-
dc.date.issued2024-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/28323-
dc.description.abstractPara llevar a cabo la investigación se tomaron 90 L de agua ácida de un efluente minero proveniente de las 03 bocaminas de nombres Hércules, Coturcan y Caridad, ubicadas en Ancash. Los ensayos químicos de la muestra determinaron una alta concentración de 249,238 mg/l de Fe, 495.025 mg/l de Zn, 13.621 mg/l de As, y 1,357 mg/l de Cd; valores que exceden los LMP establecidos en la normativa vigente (D.S. N° 010-2010-MINAM), por lo cual se debe realizar el tratamiento antes de verter al medio ambiente. Con muestras representativas se realizaron pruebas de tratamiento de aguas de mina, determinando que con una pureza del 65% de hidróxido de calcio se alcanzó % en peso de metales en el lodo generado valores de 0.539% de Pb, y 1.775% de As. Así también, las pruebas de floculación determinaron que a 600 segundos se formó el menor nivel de solidos de 139 mm correspondiente a una dosis de 2.1 ppm de floculante AR-1032, el cual fue preparado a una concentración de 0.024%. Para el diseño preliminar de los componentes de la planta de tratamiento de aguas de mina se realizaron pruebas de Jarras, determinando los valores óptimos de pH igual a 8,75 utilizando 14,8 ml de lechada de cal por cada litro de muestra a un pH inicial 3,2. Así también, se determinaron los valores óptimos de concentración de cal al 6%, una concentración de floculante AR 1032 de 0,05% a una dosificación de 3.5 ml. Las pruebas de floculación determinaron lo valores óptimos de tiempo de agitación de 5 minutos y velocidad de agitación igual a 20 rpm, valores que generan la menor turbiedad de 1.38 NTU. Las pruebas de sedimentación determinaron un tiempo óptimo de 12 minutos y una velocidad de 0,039 cm/s. En base a los resultados en laboratorio, se diseñaron los equipos para el tratamiento de aguas a escala industrial, caudal 30l/s.es
dc.description.abstractFor the development of the research, 90 L of acid water were taken from a mining effluent coming from the 03-pithead named Hércules, Coturcan and Caridad, located in Ancash. The chemical tests of the sample determined a high concentration of 249.238 mg/l of Fe, 495.025 mg/l of Zn, 13.621 mg/l of As, and 1,357 mg/l of Cd; values that exceed the LMP established in current regulations (D.S. No. 010-2010- MINAM), for which treatment must be carried out before discharging into the environment. Mine water treatment tests were carried out with representative samples, determining that with a purity of 65% of calcium hydroxide, % by weight of metals in the generated sludge values of % were reached in 0.539% of Pb and 1.775% of As. Likewise, the flocculation tests determined that at 600 seconds the lowest level of solids of 152 mm was formed corresponding to a dose of 2.1 ppm of AR-1032 flocculant, which was prepared at a concentration of 0.02%. For the preliminary design of the components of the mine water treatment plant, Jar tests were carried out, determining the optimal Ph values equal to 8.75 using 14.8 ml of milk of lime for each liter of sample to initial Ph 3,2. Likewise, the optimal values of lime concentration at 6%, an AR 1032 flocculant concentration of 0.05% at a dosage of 3.5 ml were determined. The flocculation tests determined the optimal values of stirring time of 5 minutes and stirring speed equal to 20 rpm, values that generate the lowest turbidity of 1.38 NTU. The sedimentation tests determined an optimal time of 12 minutes, and a speed of 0.039 cm/s. Based on the results obtained in the laboratory, equipment for water treatment on an industrial scale was designed.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectTratamiento de aguaes
dc.subjectPrueba de jarrases
dc.subjectTurbiedades
dc.subjectFloculaciónes
dc.subjectSedimentaciónes
dc.titleOptimización de la planta de tratamiento del agua de mina para remover arsénico y cadmio cumpliendo con la categoría 3 en el cuerpo receptor convergente al río Santaes
dc.typeinfo:eu-repo/semantics/masterThesises
thesis.degree.nameMaestro en Minería y Medio Ambientees
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Geológica, Minera y Metalúrgica. Unidad de Posgradoes
thesis.degree.levelMaestríaes
thesis.degree.disciplineMaestría en Minería y Medio Ambientees
thesis.degree.programMaestríaes
renati.advisor.orcidhttps://orcid.org/0000-0001-6790-0458es
renati.author.dni45156116-
renati.advisor.dni08111250es
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#maestroes
renati.discipline724197-
renati.jurorRosales Huamaní, Jimmy Aurelio-
renati.jurorValverde Espinoza, Santiago Gualberto-
renati.jurorCastillo Alejos, Efraín Eugenio-
renati.jurorAyala Mina, Jorge Gerardo-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.05es
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
delacruz_gc.pdf4,13 MBAdobe PDFVisualizar/Abrir
delacruz_gc(acta).pdf762,55 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf715,47 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf555,13 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI