dc.description.abstractEsta investigación se centra en el estudio del comportamiento físico-mecánico del concreto antideslave utilizando los aditivos MasterMatrix UW 450 M y CPA DISPER WR en áreas con niveles freáticos elevados. El objetivo principal es analizar las propiedades físico-mecánicas de un concreto de resistencia mediana a alta utilizando aditivos antideslave, con el fin de aplicarlo en vaciados bajo el nivel freático. La hipótesis general plantea que el uso de estos aditivos mejorará las propiedades físico-mecánicas del concreto vaciado bajo el agua, previniendo el lavado del material cementante y del agregado fino, y manteniendo la resistencia del concreto. El método de investigación aplicado es cuantitativo, específicamente un diseño experimental transversal correlacional-causal. Se emplearon tres porcentajes de aditivo MasterMatrix UW 450 M (0.40%, 0.98% y 1.56%) y un porcentaje constante de CPA DISPER WR (0.50% del peso del material cementante) para relaciones agua/cemento de 0.40, 0.45 y 0.50. Se evaluaron diversas propiedades como el asentamiento, peso unitario, fluidez de asentamiento, contenido de aire, tiempo de fraguado, pérdida de finos, resistencia a la compresión a los 7, 14 y 28 días y resistencia a la tracción a los 28 días. Los resultados indicaron que a medida que se incrementa la adición de MasterMatrix UW 450 M, el concreto presenta un buen desempeño bajo el agua con mínima pérdida de finos. Además, se observó que la resistencia a la compresión aumenta de manera proporcional al incremento de la dosificación de MasterMatrix UW 450 M.es
dc.description.abstractThis research focuses on the study of the physical-mechanical behavior of anti-slump concrete using MasterMatrix UW 450 M and CPA DISPER WR admixtures in areas with high water table. The main objective is to analyze the physical-mechanical properties of a medium to high strength concrete using antislump admixtures, in order to apply it in pours below the water table. The general hypothesis is that the use of these admixtures will improve the physical-mechanical properties of concrete poured under water, preventing the washout of the cementitious material and fine aggregate, and maintaining the strength of the concrete. The research method applied is quantitative, specifically a cross-sectional correlational-causal experimental design. Three percentages of MasterMatrix UW 450 M admixture (0.40%, 0.98% and 1.56%) and a constant percentage of CPA DISPER WR (0.50% of the weight of the cementitious material) were used for water/cement ratios of 0.40, 0.45 and 0.50. Various properties such as slump, unit weight, slump fluidity, air content, setting time, fines loss, compressive strength at 7, 14 and 28 days, and tensile strength at 28 days were evaluated. The results indicated that as the addition of MasterMatrix UW 450 M is increased, the concrete performs well under water with minimal loss of fines. In addition, it was observed that the compressive strength increases proportionally to the increase in MasterMatrix UW 450 M dosage.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectPropiedades del concretoes
dc.subjectAditivoses
dc.subjectConcretos de alta resistenciaes
dc.subjectVaciado de concretoes
dc.titleEstudio de las propiedades del concreto vaciado bajo el agua usando aditivo antideslave para concretos de mediana a alta resistenciaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Civiles
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Civiles
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Civiles
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-8956-2194es
renati.author.dni70139950-
renati.advisor.dni43420112-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline732016-
renati.jurorArrieta Freyre, Javier Eduardo-
renati.jurorCachay Huamán, Rafael-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
apaza_md.pdf2,84 MBAdobe PDFVisualizar/Abrir
apaza_md(acta).pdf863,41 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf1,4 MBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf793,02 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI