Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/28510
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Huaynalaya Rashuamán, Max | - |
dc.contributor.author | Quezada Chávez, Tonmy Richard | - |
dc.creator | Quezada Chávez, Tonmy Richard | - |
dc.date.accessioned | 2025-09-26T18:36:03Z | - |
dc.date.available | 2025-09-26T18:36:03Z | - |
dc.date.issued | 2024 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/28510 | - |
dc.description.abstract | En el Perú existen muy pocas empresas dedicadas al procesamiento de los residuos sólidos de la industria de la construcción y demolición para obtener agregados reciclados, esto es debido a una débil normativa que regule la gestión y el manejo de los residuos sólidos de la industria de la construcción y demolición, pues en la mayoría de los casos estos residuos sólidos son arrojados en botaderos informales (Organización de Evaluación y Fiscalización Ambiental [OEFA], 2014). El presente trabajo de investigación consiste en determinar la influencia del agregado grueso reciclado en concretos de mediana a baja resistencia utilizando cemento portland puzolánico tipo IP; dicha influencia se determinó mediante la valoración de las propiedades del concreto en estado fresco y endurecido. El agregado grueso reciclado, usado en las mezclas, se obtuvo de una empresa especializada en el procesamiento de residuos de concreto de la industria de la construcción y demolición ubicado en el distrito de Villa el Salvador, provincia y departamento de Lima. Se fabricaron 3 mezclas de concreto patrón con agregados naturales y 12 mezclas de concreto con cuatro porcentajes diferentes de sustitución de agregado grueso reciclado (25 %, 50 %, 75 % y 100 %) para tres valores de agua/cemento 0,60, 0,65 y 0,70. Los resultados de los ensayos del concreto en estado fresco obtenidos en la investigación mostraron que el asentamiento, peso unitario, exudación y tiempo de fraguado disminuyen respecto del concreto patrón cuando la sustitución de agregado grueso reciclado es 100 %, mientras que el contenido de aire aumenta a medida que el porcentaje de agregado reciclado incrementa. Los resultados de los ensayos del concreto en estado endurecido obtenidos mostraron que la resistencia a la compresión, tracción y flexión son similares al del concreto patrón cuando el porcentaje de sustitución de agregado grueso reciclado es 25 %. De manera complementaria se realizó la contrastación de hipótesis estadística de los diferentes grupos de concreto con sustitución de 25 %, 50 %, 75 % y 100 % respecto del grupo de concreto patrón comparando las medias de manera independiente concluyendo que los valores de asentamiento, exudación, tiempo de fraguado, resistencia a la comprensión, resistencia a la compresión diametral y resistencia a la flexión no son significativos y los valores de peso unitario y contenido de aire son significativos. Finalmente, con reemplazos de hasta 25 % de agregado grueso reciclado se determinó que los diferentes concretos estudiados se comportan favorablemente. | es |
dc.description.abstract | In Peru there are very few companies dedicated to the processing of solid waste from the construction and demolition industry to obtain recycled aggregates, this is due to weak laws that regulate the management and handling of solid waste from the construction and demolition industry, since in most cases these solid wastes are dumped in informal dumps (Organization of Environmental Evaluation and Supervision [OEFA], 2014). The present research work consists of determining the influence of recycled coarse aggregate in medium to low resistance concrete using IP type Portland puzzolanic cement; This influence was determined by evaluating the properties of the concrete in its fresh and hardened state. The recycled coarse aggregate, used in the mixtures, was obtained from a company specialized in the processing of concrete waste from the construction and demolition industry located in the district of Villa el Salvador, province and department of Lima. Three standard concrete mixes with natural aggregates and 12 concrete mixes with four different percentages of recycled coarse aggregate substitution (25%, 50%, 75% and 100%) were manufactured for three water/cement values 0,60, 0,65 and 0,70. The results of the fresh concrete tests obtained in the research showed that the settlement, unit weight, exudation and setting time decrease with respect to the standard concrete when the replacement of recycled coarse aggregate is 100%, while the air content increases. as the percentage of recycled aggregate increases. The results of the tests of the concrete in the hardened state obtained showed that the compressive, tensile and flexural strength are similar to that of the standard concrete when the percentage of replacement of recycled coarse aggregate is 25%. In a complementary manner, the statistical hypothesis contrast of the different groups of concrete with replacement of 25 %, 50 %, 75 % and 100 % was carried out with respect to the standard concrete group, comparing the means independently, concluding that the values of settlement, exudation, setting time, compressive strength, diametral compressive strength and flexural strength are not significant and the unit weight and air content values are significant. Finally, with replacements of up to 25 % of recycled coarse aggregate, it was determined that the different concretes studied behave favorably. | en |
dc.description.uri | Tesis | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Propiedades del agregado grueso | es |
dc.subject | Concreto de mediana resistencia | es |
dc.subject | Concreto de baja resistencia | es |
dc.subject | Cemento Portland | es |
dc.subject | Cemento puzolánico | es |
dc.title | Influencia del agregado grueso reciclado en concretos de mediana a baja resistencia, utilizando cemento Portland puzolánico tipo IP | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Civil | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Civil | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Civil | es |
thesis.degree.program | Ingeniería | es |
renati.advisor.orcid | https://orcid.org/0000-0002-8956-2194 | es |
renati.author.dni | 47854513 | - |
renati.advisor.dni | 43420112 | - |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es |
renati.discipline | 732016 | - |
renati.juror | Arrieta Freyre, Javier Eduardo | - |
renati.juror | Barzola Gastelú, Carlos Armando | - |
dc.publisher.country | PE | es |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es |
Aparece en las colecciones: | Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
quezada_ct.pdf | 5,95 MB | Adobe PDF | Visualizar/Abrir | |
quezada_ct(acta).pdf | 918,03 kB | Adobe PDF | Visualizar/Abrir | |
informe_de_similitud.pdf | 1,49 MB | Adobe PDF | Visualizar/Abrir | |
carta_de_autorización.pdf | 773,87 kB | Adobe PDF | Visualizar/Abrir |