dc.description.abstractSe comparó por 54 semanas dos reactores Downflow Hanging Sponge (DHS) de tercera generación de similares características denominados R-1 y R-2, compuestos cada uno por dos módulos en serie y se evaluó la remoción de coliformes termotolerantes del efluente en una primera etapa (38 semanas) de un reactor Anaerobio de Manto de Lodos y Flujo Ascendente (UASB) y en una segunda etapa (16 semanas) el efluente de un reactor UASB Tanque Séptico. Estos reactores anaerobios, se complementaron eficientemente con el sistema DHS, que es aerobio y de flujo descendente. Los parámetros de diseño fueron establecidos para un caudal de ingreso de 43.20 Ud y un tiempo de retención hidráulico de 2.27 horas con un material filtrante de poliuretano de 12.51 Kg/m3 y 94.10% de porosidad. Se obtuvo una eficiencia promedio en remoción de coliformes termotolerantes de 2.61 log y 2.24 log en cada reactor, y para el caso de la DBOs se logró una conversión del orden de 86% y 93% respectivamente. El incremento promedio de oxígeno disuelto fue de 0.79 a 6.21 mg/L en el R-1 y de 0.79 a 5.81 mg/L en el R-2; la producción promedio de lodos fue de 62.05 y 69.60 ml/d respectivamente. Los parámetros fisicoquímicos analizados tales como el oxígeno disuelto, conductividad, temperatura y pH en los efluentes de estos reactores DHS cumplen con el ECA del agua categoría 3, riego de vegetales y bebidas de animales y en el caso de la DBOs y coliformes termotolerantes se obtuvieron valores promedio que no cumplen con el ECA Agua categoría 3 pero se podría complementar el tratamiento con una unidad de desinfección para cumplir con la exigencia de la norma.es
dc.description.abstractTwo third generation Downflow Hanging Sponge (OHS) reactors of similar characteristics, called R-1 y R-2, each composed of two modules in series, were compared for 54 weeks. The removal of thermotolerant coliforms from the effluent was evaluated in a first stage (38 weeks) of an Upflow Anaerobic Sludge Blanket Reactor (UASB) and in a second stage (16 weeks) the effluent of a UASB Septic Tank reactor. These anaerobic reactors were efficiently complemented with the DHS system, which is aerobic and downflow. The design parameters were established for an inlet flow rate of 43.20 Lid and a hydraulic retention time of 2.27 hours with a polyurethane filter material of 12.51 Kg/m3 and 94.10% porosity. An average removal efficiency of thermotolerant coliforms of 2.61 log and 2.24 log was obtained in each reactor and in the case of B0O5 a conversion of 86% and 93%, respectively, was achieved. The average increase in dissolved oxygen was 0.79 to 6.21 mg/L in R-1 and 0.79 to 5.81 mg/L in R-2; the average sludge production was 62.05 and 69.60 ml/d respectively. The physicochemical parameters analyzed such as dissolved oxygen, conductivity, temperature and pH in the effluents of these DHS reactors comply with the ECA of water category 3, irrigation of vegetables and animal beverages and in the case of B0O5 and thermotolerant coliforms, average values were obtained that do not comply with the ECA Water category 3 but the treatment could be complemented with a disinfection unit to comply with the requirements of the standard.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectAguas residualeses
dc.subjectPurificaciónes
dc.subjectColiformes termotoleranteses
dc.subjectRemociónes
dc.subjectBacterias coliformeses
dc.titleRemoción de coliformes termotolerantes mediante el uso de un reactor DHS de tercera generaciónes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-6140-4266es
renati.author.dni40045686-
renati.advisor.dni10040514-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline733016-
renati.jurorSalazar Gavelán, Roger Edmundo-
renati.jurorAlarcón Cóndor, Juan Carlos-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
lazo_pl.pdf7,14 MBAdobe PDFVisualizar/Abrir
lazo_pl(acta).pdf799,17 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf1,68 MBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf1,22 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI