Title: Desempeño hidráulico de la bomba de ariete hidráulico universal con tubería de suministro de PVC
Authors: Estrada Huayta, Fleming Erick
Advisors: Olivarez Vega, Jorge Luis
Keywords: Golpe de ariete;Bombas hidráulicas;Energía hidráulica;Tuberías de cloruro de polivinilo (PVC)
Issue Date: 2025
Publisher: Universidad Nacional de Ingeniería
Abstract: La tesis consiste en describir el comportamiento hidráulico de la bomba de ariete de PVC 1”, a partir de las variables independientes h/H ∈ [2.3, 11] y L/D = {400, 500, 600}. Las hipótesis se plantearon sobre las relaciones adimensionales q/QT, Q/QT, nD/vc y η. También se estudió el caudal de suministro relativo QT/(vcD²). La investigación es experimental, para lo cual se construyó un banco de pruebas hidráulico para alturas de suministro de H = {1.4 m, 2 m, 3 m}. Se encontró un caudal de descarga máximo de 5.79 l/min, cuando h/H = 2.3 y H = 3 m. La altura de descarga máxima hmax encontrada fue de 44.8 m a caudal cero (q = 0 l/min) cuando L/D = 600 y H = 3 m. La mayor altura de descarga a caudal mínimo estudiada fue de 33.08 m con un caudal de bombeo de q = 0.31 l/min, cuando h/H = 11. La eficiencia de Rankine alcanza sus valores más altos en el rango h/H ∈ [4, 6], con un promedio de 44.3%. El caudal de suministro necesario para el funcionamiento de la bomba de ariete se encuentra entre QT ∈ [10.46 l/min, 26.68 l/min]. La relación q/QT ∈ [0.015, 0.248] indica que el bombeo efectivo está entre el 1.5% y el 24.8% del caudal de suministro. Para una relación de alturas h/H = 5 el caudal relativo es q/QT = 0.10, es decir, el 10% del caudal de su- ministro es bombeado.
The thesis consists of describing the hydraulic behavior of the 1” PVC ram pump, starting from the independent variables h/H = [2.3, 11] and L/D = {400, 500, 600}. Hypotheses we- re made on the dimensionless relationships q/QT, Q/QT, nD/vc and η. The relative supply flow rate QT/ (vcD²) was also studied. The investigation is experimental, for which a hydraulic test rig was constructed for supply heads of H = [1.4 m, 2 m, 3 m}. A maximum discharge flow rate of 5.79 l/min was found, when h/H = 2.3 and H = 3 m. The maximum discharge head hmax found was 44.8 m at zero flow rate ( q = 0 l/min), when L/D = 600 and H = 3 m. The highest discharge head at minimum flow rate studied was 33.08 m at a pumping rate of q = 0.31 l/min, when h/H = 11. Rankine efficiency reached its highest values in the range h/H = [4, 6], with an average of 44.3%. The supply flow rate required to operate the ram pump is between QT = [10.46 l/min, 26.68 l/min]. The ratio q/QT = [0.015, 0.248] indicates that the effective pumping is between 1.5% and 24.8% of the supply flow. For a head ratio h/H = 5 the relative flow rate is q/QT = 0.10, i.e., 10% of the supply flow is pumped.
URI: http://hdl.handle.net/20.500.14076/28713
Rights: info:eu-repo/semantics/openAccess
Appears in Collections:Ingeniería Sanitaria

Files in This Item:
File Description SizeFormat 
estrada_hf.pdf39,43 MBAdobe PDFView/Open
estrada_hf(acta).pdf343,12 kBAdobe PDFView/Open
informe_de_similitud.pdf628,36 kBAdobe PDFView/Open
carta_de_autorización.pdf663,61 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI