Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/28969
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGontaruk Collque, Hugo Cristhian-
dc.contributor.authorCastillo Villacorta, Jorge Luis-
dc.creatorCastillo Villacorta, Jorge Luis-
dc.date.accessioned2026-02-26T23:08:36Z-
dc.date.available2026-02-26T23:08:36Z-
dc.date.issued2025-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/28969-
dc.description.abstractEl presente trabajo se enfoca en comparar las técnicas más usadas en la determinación de cobre en el laboratorio químico ubicado en el proyecto minero Quellaveco (Mariscal Nieto, Moquegua) administrado por SGS del Perú SAC. Por ello, se describen los métodos de determinación de cobre en minerales mediante espectrometría de absorción atómica e ICP-OES y determinación de cobre en concentrados mediante volumetría, evaluando la influencia de variables operativas en la precisión y veracidad de los resultados. Se estudiaron factores como la masa de muestra, volumen de reactivos lixiviantes, temperatura de la plancha y bloque de digestión y condiciones del equipo, buscando determinar su impacto en la precisión de los métodos. Mediante un diseño experimental, se identificaron y se evaluaron variables críticas que afectan los resultados en cada método. En la absorción atómica, se determinó que la masa de la muestra, volumen de ácido nítrico y la optimización del equipo de absorción son factores significativos. En el ICP-OES, la temperatura del bloque de digestión juega un rol importante. En cuanto a la volumetría se identificaron múltiples factores significativos como la masa de la muestra, el volumen de ácido clorhídrico y varias interacciones entre factores. Los análisis revelaron que, aunque estos factores tienen un impacto considerable en los métodos analíticos, los procedimientos actuales ofrecen resultados confiables y repetibles dentro de los márgenes aceptados. Sin embargo, se recomienda una revisión periódica de las condiciones operativas, capacitación del personal, y mejoras en la estandarización de la preparación de muestras.es
dc.description.abstractThe present work focuses on comparing the most used techniques in the determination of copper in the chemical laboratory, it is located in the Quellaveco mining project (Mariscal Nieto, Moquegua) managed by SGS del Perú SAC. For this reason, it describes the methods for determining copper in minerals using atomic absorption spectrometry and ICP-OES and determining copper in concentrates using volumetry, evaluating the influence of operational variables on the precision and veracity of the results. Factors such as sample mass, volume of leaching reagents, temperature of the plate and digestion block and equipment conditions were studied, seeking to determine their impact on the precision of the methods. Through an experimental design, critical variables that affect the results in each method were identified and evaluated. In atomic absorption, it was determined that the sample mass, volume of nitric acid and the optimization of the absorption equipment are significant factors. In ICP-OES, the temperature of the digestion block plays an important role. As regards volumetry, multiple significant factors were identified, such as sample mass, volume of hydrochloric acid, and several interactions between factors. The analyses revealed that, although these factors have a considerable impact on the analytical methods, current procedures offer reliable and repeatable results within the accepted margins. However, a periodic review of the operating conditions, training of personnel, and improvements in the standardization of sample preparation are recommended.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectQuímica analíticaes
dc.subjectAnálisis químicoes
dc.subjectVariables operativases
dc.subjectFactores fisicoquímicoses
dc.titleComparación de técnicas analíticas y evaluación de factores fisicoquímicos que afectan la determinación de cobre a partir de mineraleses
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameLicenciado en Químicaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Cienciases
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineQuímicaes
thesis.degree.programLicenciaturaes
renati.advisor.orcidhttps://orcid.org/0009-0004-3543-9942es
renati.author.dni43167849-
renati.advisor.dni10527894-
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline531066-
renati.jurorTorpoco Carmen, Virginia Elizabeth-
renati.jurorDávila Ingaruca, Marcelino Eusebio-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.04.03es
Aparece en las colecciones: Química

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
castillo_vj.pdf3,22 MBAdobe PDFVisualizar/Abrir
castillo_vj(acta).pdf395,99 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf469,41 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf192,18 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI