Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/29385| Título : | Remoción de coliformes termotolerantes del efluente de un reactor UASB mediante el proceso UV/H2O2 |
| Autor : | Perales Martinez, Alec Andre |
| Asesor : | Yaya Beas, Rosa Elena |
| Palabras clave : | Peróxido de hidrógeno;Coliformes termotolerantes;Dosis UV;Procesos de oxidación avanzada |
| Fecha de publicación : | 2025 |
| Editorial : | Universidad Nacional de Ingeniería |
| Resumen : | Esta investigación evaluó la eficiencia de remoción de coliformes termotolerantes del efluente de un reactor UASB mediante la aplicación del proceso UV/H2 O2 con y sin filtración previa. Se empleo un reactor fotoquímico con lámparas UV suspendidas (Irradiancia: 4.13 mW/cm2) y un filtro de arena de lecho reducido (Tasa aproximada: 7.29 m3/m2/día).
Se estudio dos configuraciones de tratamiento, la primera aplicando el proceso UV/H2 O2 sobre el efluente del reactor UASB con dosis de H2 O2 de 112, 170 y 300 mg/l y tiempos de contacto UV de 10, 20, 30 y 60 segundos, mientras que la segunda configuración consistió en filtrar las muestras a través del filtro, para luego aplicar el proceso UV/H2 O2 con las dosis de H2 O2 de 10, 30 y 50 mg/l durante los mismos tiempos de contacto UV.
La configuración Nº01 alcanzo eficiencias entre el 85.80% y 99.83%, logrando una remoción promedio de 2.95 unidades logarítmicas con 112 mg/l de H2 O2 y una dosis UV de 60.03 mWs/cm2.
En cambio, la configuración Nº02 mostro eficiencias entre el 99.391% y 99.992%, logrando 4.20 unidades logarítmicas de remoción con solo 10 mg/l de H2 O2 y una dosis UV de 189.15 mW/cm2.
Los resultados demostraron que el proceso de filtración previo mejora la eficiencia del proceso UV/H2 O2, permitiendo alcanzar mayores remociones de coliformes termotolerantes con menores dosis de peróxido, cumpliendo la normativa nacional. This research evaluated the removal efficiency of thermotolerant coliforms from the effluent of a UASB reactor through the application of the UV/H2 O2 process, with and without prior filtration. A photochemical reactor equipped with suspended UV lamps (Irradiance: 4.13 mW/cm2) and a compact sand bed filter (Approximate filtration rate: 7.29 m3/m2/day) was used. Two treatment configurations were studied. The first involved applying the UV/H2 O2 process directly to the UASB effluent, using H2 O2 doses of 112, 170, and 300 mg/L and UV contact times of 10, 20, 30, and 60 seconds. The second configuration consisted of filtering the samples through the sand filter prior to applying the UV/H2 O2 process, with H2 O2 doses of 10, 30, and 50 mg/L under the same UV contact times. Configuration No. 1 achieved removal efficiencies ranging from 85.80% to 99.83%, with an average log reduction of 2.95 using 112 mg/L of H2 O2 and a UV dose of 60.03 mW/cm2. In contrast, Configuration No. 2 exhibited efficiencies between 99.391% and 99.992%, reaching a 4.20-log reduction with only 10 mg/L of H2 O2 and a UV dose of 189.15 mW/cm2. The results demonstrated that the prior filtration process enhances the efficiency of the UV/H2 O2 treatment, enabling higher thermotolerant coliform removal with lower hydrogen peroxide doses, in compliance with national regulations. |
| URI : | http://hdl.handle.net/20.500.14076/29385 |
| Derechos: | info:eu-repo/semantics/openAccess |
| Aparece en las colecciones: | Ingeniería Sanitaria |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| perales_ma.pdf | 2,59 MB | Adobe PDF | Visualizar/Abrir | |
| perales_ma(acta).pdf | 394,92 kB | Adobe PDF | Visualizar/Abrir | |
| informe_de_similitud.pdf | 198,43 kB | Adobe PDF | Visualizar/Abrir | |
| carta_de_autorización.pdf | 340,32 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: