Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.14076/29386| Title: | Cálculo de la carga orgánica superficial en un reactor MBBR para el tratamiento de desagüe doméstico pretratado en CITRAR |
| Authors: | Yerba Pacompia, Walter Enrique |
| Advisors: | Yaya Beas, Rosa Elena |
| Keywords: | Tratamiento de aguas residuales;Reactores biológicos;Agua residual doméstico pretratado;Portador de biopelícula;Aguas residuales domésticas |
| Issue Date: | 2025 |
| Publisher: | Universidad Nacional de Ingeniería |
| Abstract: | Esta investigación evaluó la carga orgánica superficial en un reactor aerobio de biopelícula de lecho móvil (MBBR) de un desagüe doméstico pretratado en Citrar; planteando como hipótesis que aplicar carga orgánica inferior a 20 g DBO5/m².d permite una eficiencia de remoción de la DBO5 superior al 80% en un reactor MBBR. La evaluación de la carga orgánica fue en tres periodos: periodo puesta en marcha, primer periodo y segundo periodo con caudales de operación promedio de 200.75, 198.74 y 298.22 L/día respectivamente; y fue durante 25 semanas.
El reactor MBBR fue de dos etapas en serie, con volumen en cada etapa de 40 L, sección rectangular y usó un sistema aireado. El portador de biopelícula utilizado posee un área de superficie específica de 2166.47 m2/m3 y porcentaje de vacío del 84.19%; cada etapa del reactor MBBR consistió con un porcentaje de llenado del 32.55%.
Finalmente, se concluyó que en el primer periodo una carga orgánica superficial aplicada (SALR) promedio de 6.53 ± 0.79 g DBO5/m2.d obtiene una eficiencia de remoción promedio de la DBO5 en el reactor MBBR del 93.05 ± 3.05%; y que en el segundo periodo una SALR promedio de 10.05 ± 1.56 g DBO5/m2.d obtiene una eficiencia de remoción promedio de la DBO5 en el reactor MBBR del 88.76 ± 4.29%. Además, se concluye que el portador utilizado remueve la DBO y la DQO. This study evaluated the surface organic loading in an aerobic moving bed biofilm reactor (MBBR) from a pretreated domestic sewage treatment plant in Citrar; it is being formulated that applying an organic loading of less than 20 g BOD5/m²/d allows for a BOD5 removal efficiency greater than 80% in an MBBR reactor. The evaluation of the organic load was over three periods: the start-up period, the first period, and the second period, with average operating flow rates of 200.75, 198.74, and 298.22 L/day, respectively; and it was during 25 weeks. The MBBR reactor was a two-stage reactor in series, with a volume of 40 L per stage, a rectangular section, and an aerated system. The biofilm carrier used had a specific surface area of 2166.47 m2/m3 and an empty percentage of 84.19%; each stage of the MBBR reactor consisted of a fill percentage of 32.55%. Finally, it was concluded that in the first period, an average applied organic surface loading (SALR) of 6.53 ± 0.79 g BOD5/m2.d obtained an average BOD5 removal efficiency in the MBBR reactor of 93.05 ± 3.05%; and that in the second period, an average SALR of 10.05 ± 1.56 g BOD5/m2.d obtained an average BOD5 removal efficiency in the MBBR reactor of 88.76 ± 4.29%. Furthermore, it was concluded that the carrier used removes BOD and COD. |
| URI: | http://hdl.handle.net/20.500.14076/29386 |
| Rights: | info:eu-repo/semantics/openAccess |
| Appears in Collections: | Ingeniería Sanitaria |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| yerba_pw.pdf | 5,99 MB | Adobe PDF | View/Open | |
| yerba_pw(acta).pdf | 175,12 kB | Adobe PDF | View/Open | |
| informe_de_similitud.pdf | 183,57 kB | Adobe PDF | View/Open | |
| carta_de_autorización.pdf | 300,76 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: